Sign In | Join Free | My fnxradio.com
China Knkong Electric Co.,Ltd logo
Knkong Electric Co.,Ltd
Knkong Electric Co.,Ltd
Active Member

5 Years

Home > Metal Enclosed Switchgear >

LV 1000V Solid Insulated Switchgear Withdrawable Switchgear

Knkong Electric Co.,Ltd
Contact Now

LV 1000V Solid Insulated Switchgear Withdrawable Switchgear

Brand Name : KNKONG

Model Number : GCK

Certification : ISO IEC GB

Place of Origin : China

MOQ : 1

Price : USD 10000-20000 Each

Payment Terms : L/C, T/T

Supply Ability : 500 unit per month

Delivery Time : 15 working days

Packaging Details : Standard export packaging

Insulation voltage : 660-1000V

Working voltage : 380-660V

Frequency : 50Hz

Maximum current of feeder circuit : 3150A

OEM/ODM : Available

Maximum current of drawer circuit : 3150A

Contact Now

LV 1000V Solid Insulated Switchgear Withdrawable Switchgear

GCK Type Low Voltage Switchgear 400V 690V LV panels LV switchgear

400/690V, 50/60 HZ ,400~6300A
Modular design, easily assembly
enclosure: Max. IP40
CCC,ISO9001,GB7251,IEC439
Send us your SLD (Single Line Drawing) or requirements, we design the switchgear plan for you
Inquire

Product Introduction

General

GCK should be an improved economical type of MNS. The vertical row has no plastic functional panels. The door is fixed on the frame. After the door is opened, the drawer can be pulled out. G--cabinet structure; C--drawable type; K--control center

Working environment

1. The ambient air temperature should not be higher than +40℃, not lower than -5℃, the average temperature within 24h should not be higher than +35℃ if it exceeds, it needs to be derated and run according to the actual situation;
2. Indoor use: the altitude of the place of use shall not exceed 2000m
3. The relative temperature of the surrounding air should not exceed 50% when the temperature is +40℃. A larger relative temperature is allowed at a lower temperature, such as 90% when the temperature is +20℃. It should be considered that condensation may occur accidentally due to temperature changes. The impact of exposure;
4. When the device is installed, the inclination from the vertical plane does not exceed 5°C, and the entire group of cabinets is relatively flat (in accordance with the GBJ232-82 standard);
5. The device should be installed in a place where there is no severe vibration and impact, and where the electrical components are not corroded;
6. If the user has special requirements, it can be resolved through consultation with the manufacturer.
Technical Parameters
Rated insulation voltage: AC 660V, AC 1000V
Rated working voltage: AC 380 V, AC 660 V
Rated frequency: 50Hz
Maximum current of feeder circuit: 3150A
Maximum current of drawer circuit: 3150A
Maximum capacity of control motor: 320KW
Horizontal bus peak withstand current (0.1S): 63KA, 105KA, 176KA
Horizontal busbar short-time withstand current (1S): 30 KA, 50 KA, 80 KA, 100 KA
Vertical bus peak withstand current (0.1S): 63 KA, 105 KA
Vertical busbar short-time withstand current (1S): 30 KA, 50 KA
Rated power frequency withstand voltage (1min): 2500V
Secondary power frequency withstand voltage (1min): 2500V
Protection level: IP30, IP40
Dimensions width * depth * height mm: 600 (800, 1000) * 800 (1000) * 2200

Product Tags:

1000V Withdrawable Switchgear

      

1000V Solid Insulated Switchgear

      

LV Solid Insulated Switchgear

      
Wholesale LV 1000V Solid Insulated Switchgear Withdrawable Switchgear from china suppliers

LV 1000V Solid Insulated Switchgear Withdrawable Switchgear Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Knkong Electric Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)